Air Ducts and Related Sales Items

Flexible Ducts

Sales Item: Fastener Type

• A vinyl tube that features high flexibility and minimal air leakage

Sales Item: Ring Type

• Individual rings will maintain cylindrical shape of the tube

Combination Item: Fastener Type Spiral Tube

• It will maintain its full diameter regardless of the curves.
• Less leakage due to fastener connection

Combination Item: Spiral Tube

• It will maintain its full diameter regardless of the curves.

Connecting the ducts (Spiral Tube)

Warp one of the tubes and slide the other tube into a warped tube. Fix the warp and then tie them together if they have a string attached to them.

*Flexible tubes cannot be used for a negative pressure.

Use them for the discharge side of the fans.

Return to the Top

Hard Ducts

Sales Item: Colgate Duct (Galvanized Iron Sheet)
Durable and inflammable tube. Suitable for cases where the air becomes negative pressure (suction side of the fan), or the site that uses fire.

Sales Item: Helical Duct

Sales Item: SGP (Carbon Steel Pipes)

Relates Items

Sales Item: Reducer

Sales Item: Elbow

Necessary items for attaching the tubes to the fans

Specifications

Fastener Type Spiral Tube

Product Code ZAZ 40105 001 ZAZ 50105 001 ZAZ 60105 001
Management Code 0015T 00520 0015N
Diameter(mm) 400 500 600
Set Length (m) 10
Wire Pitch (mm) 150
Material
PVC Tarpaulin (Certified for Fire Prevention)
Material Thickness (mm) 0.35
Pressure(kPa) 8.61 6.89 5.74
Mass (kg) 17.5 20.2 23.0
Catalogue

Spiral Tube

Product Code ZAZ 30053 001 ZAZ 40053 001 ZAZ 50053 001 ZAZ 60053 001
Management Code 00573 00E46 00E45 00K49
Diameter(mm) 300 400 500 600
Set Length (m) 5

*Uses PVC tarpaulin (certified fireproof material)
*Fastener type spiral tube cannot be attached to fans (the fan’s diameter to bigger).
*Requires duct reducers to attach them on Silent Fans and Contra Fans.

*Be mindful of which sides of the fans to attach the ducts.

Return to the Top

FAQ

Can ducts be set on the either sides of the fans?

It depends on the type of ducts.
Flexible Ducts – Only on the discharge side of fans
Hard Ducts – For both discharge and suction sides.

Contact Us

AKTIO Corporation – Engineering Department:
Address: Tokyo DL Center 4F, 3-6-41 Shinsuna, Koto-ku, Tokyo, 136-0075

Return to the Top