Electromagnetic Flowmeter
Features
・By inserting this along the pipeline, it not only measures and displays the flow inside the pipe, but also shows integrated values.
The data can be sent outside of the tunnel, which allows remote monitoring and recording.
・To ensure the precise measurement of the muck, even at low velocity, parts that come in contact with the muck use a different material than the original product.
Specifications
Product Code | RC3 006P0 002 | RC3 008P0 002 | RC3 00AP0 002 | |
---|---|---|---|---|
Maker | Yokogawa Electric Corp. | |||
Model | AXF150G/ 40KF | AXF200G/ 40KF | AXF250G/ 40KF | |
Pipe Diameter | 6B Low Velocity | 8B Low Velocity | 10B Low Velocity | |
Min. Velocity(m/s) | 0.05 | |||
Min. Flow (m3/min) | 0.060 | 0.094 | 0.150 | |
Joint Part Flange Type | JIS40K | |||
Mass(kg) | 40 | 97 | 120 |
Contact Us
AKTIO Corporation – Engineering Department:
Address: Tokyo DL Center 4F, 3-6-41 Shinsuna, Koto-ku, Tokyo, 136-0075