Muck Pump / Hydraulic Unit
As the method can mitigate the cause of dust hazards and slurry ruptures, muck
pumping is gaining popularity as a unique muck transport method for a tunnel construction
sites. There are two types of pumps by their purposes: tunnel-face and relay.
Muck Pump
Hydraulic Unit
Much Pumping Flow
[1] P0 Pump [2] Hydraulic Unit
The pump is directly installed on a screw conveyor of a shield TBM, and sends excavated muck to a subsequent pump. The hydraulic unit is installed on the nearest trailing gear.
[3] Earth-Pressure Pump Control Panel
Allows controlling the pump system by placing remote control panel near the shield operator panel. (Installed on the operator’s cavin).
[4] Low Velocity Flowmeter
By inserting it between the pipes, it measures and displays the flow of the pumped earth. It can also remotely analyze and record data.
[5] Hydraulic Unit [6] P1 Pump
The relay pump system that receives muck from P0 pump, and then relays it to asubsequent pump. An additional relay pump will be installed, depending on the excavation distance.
[7] Snake-Type Stretchable Pipe
Conjoint link of pipes that extend and retracts for the pipeline extension. It features high pressure resilience and compatibility for a curved tunnel.
[8] Noise Damper
The equipment dampens the noise and shocks from a sudden change in pressure inside the pipes while pumping is in progress.
Specifications
■Muck Pump
KE1 | ||||||
Product Code | 03000 002 | 15000 003 | 08000 002 | 12000 002 | 15000 002 | |
Maker | Klein | Putzmeister | ||||
Model | KIP254 | KIP98 | KOS708 | KOS1012 | KOS1415 | |
Theoretical Max. Dispense Amount(m3/h) | 30 | 150 | 80 | 120 | 150 | |
Theoretical Max. Dispense Pressure(MPa{kgf/cm2}) | 5{51} | 3{31} | 5{51} | |||
Layout | Length (mm) | 3,800 | 6,000 | 3,873 | 4,873 | 5,633 |
Width (mm) | 600 | 1,080 | 1,020 | 1,022 | ||
Height (mm) | 1,000 | 820 | 725 | 739 | ||
Mass (kg) | 1,700 | 3,500 | 1,800 | 2,000 | 2,300 |
■Hydraulic Unit
KE2 | |||||||
Product Code | 41030 002 | 41160 002 | 41055 001 | 41075 001 | 41090 001 | 41160 001 | |
Maker | Klein | Putzmeister | |||||
Model | HPU-E30 | HPU-E160 | HA55 | HA75 | HA90 | HA160 | |
Frequency (Hz) | 50/60 Dual Purpose | ||||||
Voltage (V) | 400/440 | ||||||
Motor Output (kW) | 30/35 | 160/186 | 55/63 | 75/88 | 90/106 | 160/186 | |
Layout | Length (mm) | 1,000 | 3,100 | 2,710 | 2,890 | 2,800 | |
Width (mm) | 500 | 1,100 | 800 | 1,260 | |||
Height (mm) | 700 | 1,560 | 1,615 | 1,694 | 1,685 | ||
Mass (kg) | 400 | 4,500 | 1,900 | 2,220 | 2,000 | 2,800 |
Whenever there is a / in specifications, the left is for 50Hz, and the right is for 60Hz power.
FAQ
Contact Us
AKTIO Corporation – Engineering Department:
Address: Tokyo DL Center 4F, 3-6-41 Shinsuna, Koto-ku, Tokyo, 136-0075