{"id":11455,"date":"2013-11-04T00:00:55","date_gmt":"2013-11-03T15:00:55","guid":{"rendered":"https:\/\/www.eg.aktio.co.jp\/en\/?p=11455"},"modified":"2023-02-20T16:21:07","modified_gmt":"2023-02-20T07:21:07","slug":"muck_pump_hydraulic_unit","status":"publish","type":"post","link":"https:\/\/www.eg.aktio.co.jp\/en\/07tunnel\/g01-shield\/muck_pump_hydraulic_unit\/","title":{"rendered":"Muck Pump \/ Hydraulic Unit"},"content":{"rendered":"<div id=\"product\">\n<h1>Muck Pump \/ Hydraulic Unit<\/h1>\n<div id=\"local-nav\">\n<div><a href=\"#detail_tokucyou\">Features<\/a><a href=\"#shiyou\">Specifications<\/a><a href=\"#FAQ\">FAQ<\/a><a href=\"#toi\">Contact Us<\/a><\/div>\n<\/div>\n<div id=\"detail_tokucyou\">\n<p>As the method can mitigate the cause of dust hazards and slurry ruptures, muck<br \/> pumping is gaining popularity as a unique muck transport method for a tunnel construction<br \/> sites. There are two types of pumps by their purposes: tunnel-face and relay.<\/p>\n<div class=\"row\">\n<div class=\"col-sm\">\n<h2 class=\"h2half\">Muck Pump<\/h2>\n<p><img decoding=\"async\" alt=\"\" src=\"https:\/\/www.eg.aktio.co.jp\/en\/product_img\/dosya-assou-pomp_yuatsu-unit01_01.jpg\" width=\"320\" \/><\/p>\n<p><img decoding=\"async\" alt=\"\" src=\"https:\/\/www.eg.aktio.co.jp\/en\/product_img\/dosya-assou-pomp_yuatsu-unit01.jpg\" width=\"320\" \/><\/p>\n<\/div>\n<div class=\"col-sm\">\n<h2 class=\"h2half\">Hydraulic Unit<\/h2>\n<p><img decoding=\"async\" alt=\"\" src=\"https:\/\/www.eg.aktio.co.jp\/en\/product_img\/dosya-assou-pomp_yuatsu-unit02_01.jpg\" width=\"320\" \/><\/p>\n<p><img decoding=\"async\" alt=\"\" src=\"https:\/\/www.eg.aktio.co.jp\/en\/product_img\/dosya-assou-pomp_yuatsu-unit02.jpg\" width=\"320\" \/><\/p>\n<\/div>\n<\/div>\n<p class=\"pagetop\"><a href=\"#top\">Return to the Top<\/a><\/p>\n<h4>Much Pumping Flow<\/h4>\n<p><img decoding=\"async\" alt=\"\" src=\"https:\/\/www.eg.aktio.co.jp\/en\/product_img\/dosya-assou-pomp_yuatsu-unit03.jpg\" \/><\/p>\n<p><span class=\"text_bold\">[1] P0 Pump [2] Hydraulic Unit<\/span><\/p>\n<p>The pump is directly installed on a screw conveyor of a shield TBM, and sends excavated muck to a subsequent pump. The hydraulic unit is installed on the nearest trailing gear.<\/p>\n<p><span class=\"text_bold\">[3] Earth-Pressure Pump Control Panel<\/span><\/p>\n<p>Allows controlling the pump system by placing remote control panel near the shield operator panel. (Installed on the operator&#8217;s cavin).<\/p>\n<p><span class=\"text_bold\">[4] Low Velocity Flowmeter<\/span><\/p>\n<p>By inserting it between the pipes, it measures and displays the flow of the pumped earth. It can also remotely analyze and record data.<\/p>\n<p><span class=\"text_bold\">[5] Hydraulic Unit [6] P1 Pump<\/span><\/p>\n<p>The relay pump system that receives muck from P0 pump, and then relays it to asubsequent pump. An additional relay pump will be installed, depending on the excavation distance.<\/p>\n<p><span class=\"text_bold\">[7] Snake-Type Stretchable Pipe<\/span><\/p>\n<p>Conjoint link of pipes that extend and retracts for the pipeline extension. It features high pressure resilience and compatibility for a curved tunnel.<\/p>\n<p><span class=\"text_bold\">[8] Noise Damper<\/span><\/p>\n<p>The equipment dampens the noise and shocks from a sudden change in pressure inside the pipes while pumping is in progress.<\/p>\n<\/div>\n<p><a id=\"shiyou\" name=\"shiyou\"><\/a><\/p>\n<div id=\"detail_shiyou\">\n<h3>Specifications<\/h3>\n<p>\u25a0Muck Pump<\/p>\n<div class=\"scroll-table\">\n<table>\n<tbody>\n<tr>\n<th colspan=\"2\">\u00a0<\/th>\n<td class=\"code_new\" colspan=\"5\">KE1\u00a0<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Product Code<\/th>\n<td class=\"code_new\">03000 002<\/td>\n<td class=\"code_new\">15000 003<\/td>\n<td class=\"code_new\">08000 002<\/td>\n<td class=\"code_new\">12000 002<\/td>\n<td class=\"code_new\">15000 002<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Maker<\/th>\n<td colspan=\"2\">Klein<\/td>\n<td colspan=\"3\">Putzmeister<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Model<\/th>\n<td>KIP254<\/td>\n<td>KIP98<\/td>\n<td>KOS708<\/td>\n<td>KOS1012<\/td>\n<td>KOS1415<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Theoretical Max. Dispense Amount(m<sup>3<\/sup>\/h)<\/th>\n<td>30<\/td>\n<td>150<\/td>\n<td>80<\/td>\n<td>120<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Theoretical Max. Dispense Pressure(MPa{kgf\/cm<sup>2<\/sup>})<\/th>\n<td colspan=\"2\">5\uff5b51\uff5d<\/td>\n<td colspan=\"2\">3\uff5b31\uff5d<\/td>\n<td>5\uff5b51\uff5d<\/td>\n<\/tr>\n<tr>\n<th rowspan=\"3\">Layout<\/th>\n<th>Length (mm)<\/th>\n<td>3,800<\/td>\n<td>6,000<\/td>\n<td>3,873<\/td>\n<td>4,873<\/td>\n<td>5,633<\/td>\n<\/tr>\n<tr>\n<th>Width (mm)<\/th>\n<td>600<\/td>\n<td>1,080<\/td>\n<td>1,020<\/td>\n<td colspan=\"2\">1,022<\/td>\n<\/tr>\n<tr>\n<th>Height (mm)<\/th>\n<td>1,000<\/td>\n<td>820<\/td>\n<td>725<\/td>\n<td colspan=\"2\">739<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Mass (kg)<\/th>\n<td>1,700<\/td>\n<td>3,500<\/td>\n<td>1,800<\/td>\n<td>2,000<\/td>\n<td>2,300<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>\u25a0Hydraulic Unit<\/p>\n<div class=\"scroll-table\">\n<table>\n<tbody>\n<tr>\n<th colspan=\"2\">\u00a0<\/th>\n<td class=\"code_new\" colspan=\"6\">KE2\u00a0<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Product Code<\/th>\n<td class=\"code_new\">41030 002<\/td>\n<td class=\"code_new\">41160 002<\/td>\n<td class=\"code_new\">41055 001<\/td>\n<td class=\"code_new\">41075 001<\/td>\n<td class=\"code_new\">41090 001<\/td>\n<td class=\"code_new\">41160 001<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Maker<\/th>\n<td colspan=\"2\">Klein<\/td>\n<td colspan=\"4\">Putzmeister<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Model<\/th>\n<td>HPU-E30<\/td>\n<td>HPU-E160<\/td>\n<td>HA55<\/td>\n<td>HA75<\/td>\n<td>HA90<\/td>\n<td>HA160<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\" height=\"19\">Frequency (Hz)<\/th>\n<td colspan=\"6\">50\/60 Dual Purpose<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Voltage (V)<\/th>\n<td colspan=\"6\">400\/440<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Motor Output (kW)<\/th>\n<td>30\/35<\/td>\n<td>160\/186<\/td>\n<td>55\/63<\/td>\n<td>75\/88<\/td>\n<td>90\/106<\/td>\n<td>160\/186<\/td>\n<\/tr>\n<tr>\n<th rowspan=\"3\">Layout<\/th>\n<th>Length (mm)<\/th>\n<td>1,000<\/td>\n<td>3,100<\/td>\n<td colspan=\"2\">2,710<\/td>\n<td>2,890<\/td>\n<td>2,800<\/td>\n<\/tr>\n<tr>\n<th>Width (mm)<\/th>\n<td>500<\/td>\n<td>1,100<\/td>\n<td colspan=\"3\">800<\/td>\n<td>1,260<\/td>\n<\/tr>\n<tr>\n<th>Height (mm)<\/th>\n<td>700<\/td>\n<td>1,560<\/td>\n<td colspan=\"2\">1,615<\/td>\n<td>1,694<\/td>\n<td>1,685<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Mass (kg)<\/th>\n<td>400<\/td>\n<td>4,500<\/td>\n<td>1,900<\/td>\n<td>2,220<\/td>\n<td>2,000<\/td>\n<td>2,800<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Whenever there is a \/ in specifications, the left is for 50Hz, and the right is for 60Hz power.<\/p>\n<p class=\"pagetop\"><a href=\"#top\">Return to the Top<\/a><\/p>\n<\/div>\n<p><a id=\"FAQ\" name=\"FAQ\"><\/a><\/p>\n<div id=\"detail_faq\">\n<h3>FAQ<\/h3>\n<div class=\"faq_area\">FAQ are not registered at the moment.<\/div>\n<\/div>\n<p><a id=\"toi\" name=\"toi\"><\/a><\/p>\n<div id=\"detail_toi\">\n<h3>Contact Us<\/h3>\n<p class=\"toiawase\">AKTIO Corporation &#8211; Engineering Department: <img decoding=\"async\" alt=\"\" src=\"https:\/\/www.eg.aktio.co.jp\/en\/wp-content\/themes\/aktioeg_en_new\/images\/mailadd_toi.gif\" \/><br \/> Address: Tokyo DL Center 4F, 3-6-41 Shinsuna, Koto-ku, Tokyo, 136-0075<\/p>\n<p class=\"pagetop\"><a href=\"#top\">Return to the Top<\/a><\/p>\n<\/div>\n<p><!--detail_toi --><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Muck Pump \/ Hydraulic Unit FeaturesSpecificationsFAQContact Us As the method can mitigate the cause of dust hazards and slurry ruptures, muck pumping is gaining popularity as a unique muck transport m<\/p>\n","protected":false},"author":1,"featured_media":11449,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[10],"tags":[],"_links":{"self":[{"href":"https:\/\/www.eg.aktio.co.jp\/en\/wp-json\/wp\/v2\/posts\/11455"}],"collection":[{"href":"https:\/\/www.eg.aktio.co.jp\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.eg.aktio.co.jp\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.eg.aktio.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eg.aktio.co.jp\/en\/wp-json\/wp\/v2\/comments?post=11455"}],"version-history":[{"count":16,"href":"https:\/\/www.eg.aktio.co.jp\/en\/wp-json\/wp\/v2\/posts\/11455\/revisions"}],"predecessor-version":[{"id":19103,"href":"https:\/\/www.eg.aktio.co.jp\/en\/wp-json\/wp\/v2\/posts\/11455\/revisions\/19103"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.eg.aktio.co.jp\/en\/wp-json\/wp\/v2\/media\/11449"}],"wp:attachment":[{"href":"https:\/\/www.eg.aktio.co.jp\/en\/wp-json\/wp\/v2\/media?parent=11455"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.eg.aktio.co.jp\/en\/wp-json\/wp\/v2\/categories?post=11455"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.eg.aktio.co.jp\/en\/wp-json\/wp\/v2\/tags?post=11455"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}